director of photography, DIT, peter gray, dp, cinematography, dop, cinematographers, lighting cameraman, videographers, dv, high definition, 24p, digital films, HDW-F900, CineAlta, Varicam, AJ-HDC27F, HDC-F950, Pro 35, Viper, SRW-1, HDW-700A, 70mm, independent films, lighting directors, filmmakers, filmmaking

VTR Menu Settings for the Varicam H

line.gif - 3.0 K



Please note that a removable, camera setup card (MultiMediaCard) containing V-M1 or F files can not be loaded into the new Model H Varicam, or vise versa. In other words, the files are NOT interchangeable. The file syntax is slightly different between the newest and the earlier models of the Varicam leading to this incompatibility.



As with the Varicam F, the settings below can be recorded to a removable MultiMediaCard (flash card) directly from the Varicam H. Then they can be viewed, via a card reader, on a standard computer (using Windows "Notepad" for example). The card format is shown below. It works both ways, so changes to these Scene File settings can be made via computer (taking care to use the proper syntax), and copied back to the MultiMediaCard with a card reader/writer, and from there read back into the Varicam again. Remembering once again, that F files are not interchangeable with H files, or vise versa.



Note that the Recorder Section has it own VTR INITIALIZE MENU, and VTR CARD READ/WRITE MENU. This is completely separate from the Camera Head Menus. It also has a DATE TIME MENU (for setting the current date and time) and a DIAGNOSTIC MENU for displaying information about the recorder section which is entirely independent of the removable, camera-setup card.



Commonly Used Shortcuts for Quickly Adjusting Key Items in the VTR Menus:

VTR MAIN MENU >>> BATTERY/TAPE >>> BATTERY SELECT >>>> XXXXXXX
VTR MAIN MENU >>> FUNCTION >>> COMPRESSION MODE >>> DARK / NORMAL
VTR MAIN MENU >>> MONITOR MARKER >>> FRAME MARK >>> ON / OFF
VTR MAIN MENU >>> MIC/AUDIO >>> TEST TONE >>> ON / OFF



New Menu Items Added with the New H Firmware:

00010012 COMPRESSION MODE DARK or NORMAL
00030010 A/V SYNCHRO ON or OFF
00120003 SAFETY ZONE ON or OFF
00120004 CENTER MARKER ON or OFF
00120005 FRAME SIG 4:3, 14:9, VISTA 1:1.85, and CNSCO
00120006 FRAME MARK ON or OFF
00050007 COMPRESSION(IND) ON or OFF
00060015 DIONIC90(TYPE)(MODE)(MANUAL VOLT) new battery
00060016 DIONIC160(TYPE)(MODE)(MANUAL VOLT) new battery
00060017 NP-L50(TYPE)(MODE)(MANUAL VOLT) new battery
00060018 ENDURA50(TYPE)(MODE)(MANUAL VOLT) new battery
00060019 ENDURA-D(TYPE)(MODE)(MANUAL VOLT) new battery



Key To Color Coding:
All Values shown in Yellow are the Factory Default Settings
All Values shown in Red are suggestions, but may be set according to your Particular Application or Personal Preference


CARD Ver 0002.00
HDC-27H
M Ver 0002.00
S Ver 0002.00

FUNCTION MENU

00010001 NEWS REC MODE OFF (Sets extended recording time after record stop in 0.2 second increments up to 2 seconds.)
00010002 HUMID OPE OFF (If condensation forms, recorder is disabled automatically - except for the power and eject buttons.)
00010003 REC START NORMAL (Sets how the start of recording is displayed.)
00010004 PAUSE TIMER 10 (Selects how long the REC PAUSE mode is held - options are 10, 20, 30, 60 minutes.)
00010005 RETAKE MODE OFF (If ON, Retake Button rewinds tape back to the beginning of the last recording or take.)
00010006 HD SDI OUT SIDE SW (Output according to the position of the switch on the side of the camera.)
00010007 INTERVAL REC MODE OFF (Selects Interval Recording modes.)
00010008 INTERVAL REC TIME(SEC) 00 (When Record Time is set to less than 1 second, initial record time will be 1 second.)
00010008 INTERVAL REC TIME(FRAME) 10 (Sets the Interval Pause Time between capture events in frames.)
00010009 INTERVAL PAUSE TIME(HOUR) 00 (Sets the Interval Pause Time between capture events in hours.)
00010009 INTERVAL PAUSE TIME(MIN) 00 (Sets the Interval Pause Time between capture events in minutes.)
00010009 INTERVAL PAUSE TIME(SEC) 02 (Sets the Interval Pause Time between capture events in seconds.)
00010010 ECU REC CHK SW R.REVIEW (A Record Review operation is performed when you press the Record Check Switch on the ECU. Option is RETAKE.)
00010011 CHARACTER ON SDI STATUS (The Menus and the Status Information are embedded in the HD-SDI signal. Option Menus only.)
00010012 COMPRESSION MODE DARK (Assigns proportionally more digital code values (bits) for the darker regions of the CCD range, than for the brighter parts. This means that the shadow parts of the image can potentially look better using this new feature, with more tonality and less compression artifacts.)

BATTERY/TAPE MENU

00020001 BATTERY SELECT PRO14 (Selects the type of onboard battery used on the camera. The Anton/Bauer PRO14 is the default option.)
00020002 EXT DC IN SELECT AC_ADPT (Selects the source of power connected to the DC IN socket.)
00020003 BATT.NEAR END ALARM OFF (Sets an audible warning tone to trigger when the onboard battery is nearing the end of its charge. Normally leave off if recording sound.)
00020004 BATT NEAR END CANCEL OFF (Used to cancel the audible warning tone when the onboard battery is nearing the end of its charge.)
00020005 BATT.END ALARM OFF (Sets an audible warning tone to trigger when the onboard battery is depleted. Normally leave OFF if recording double-system audio. )
00020006 BATT REMAIN FULL 70% (This sets how the 7-segment scale works in the LCD display window on the side of the camera indicating a battery's level of charge. A battery with a charge of 70% or more will indicate full with all 7 segments lit. The other option is 100%.)
00020008 TAPE NEAR END ALARM OFF (Sets an audible warning tone to trigger when the remaining tape is nearing the end.)
00020009 TAPE NEAR END TIME 2min (The above can be triggered at either 3 minutes or 2 minutes. The default is 2 minutes.)
00020010 TAPE END ALARM OFF (Sets an audible warning tone to trigger when the tape has reached the end. Normally leave OFF if recording double-system audio.)
00020011 TAPE REMAIN/ 3min (This sets how the scale works in the LCD display window on the side of the camera indicating remaining tape time. One segment can indicate either 3 minutes (default) or 5 minutes.)

MIC/AUDIO MENU

00030001 FRONT MIC POWER OFF (Turns the phantom power to the front microphone ON or OFF.)
00030002 MIC LOWCUT CH1 OFF (For setting the High Pass Filer for the CH1 mic input. Three modes: FRONT, REAR, F&R, and OFF available.)
00030003 MIC LOWCUT CH2 OFF (For setting the High Pass Filer for the CH2 mic input. Three modes: FRONT, REAR, F&R, and OFF available.)
00030004 LIMITER OFF (Turns the Audio Limiter ON or OFF.)
00030005 TEST TONE OFF (Can select ALWAYS to have the camera generate a 1KHz tone internally when color bars are selected.)
00030006 REC CH3/CH4 CH1/2 (Selects what source is recorded to CH3&4. A copy of CH1&2, or a discreet source.)
00030007 CUE SELECT SIDE SW (Selects the audio source to be recorded on the Cue Track.)
00030008 CUE REC ON (Turns Cue Track recording ON or OFF.)
00030009 EMBEDDED AUDIO(60Hz) OFF (Allows embedded audio in the HD-SDI stream to be output when the System Frequency is set to pure 60Hz.)
00030010 A/V SYNCHRO OFF (At low frame rates, the images lag behind the sound. Turning this feature ON attempts to adjust this lag time for better synchronization.)

TIMECODE/USER BIT MENU

00040001 TC MODE NDF (For selecting Drop Frame (DF) Timecode, or Non Drop Frame (NDF) Timecode. Normally NDF for production shooting.)
00040002 UB MODE DATE (Selects what is to be written to LTC User Bits. Five Options: USER, DATE, TIME, EXT, or TCG.)
00040003 TCG SET HOLD OFF (ON to store Timecode when the camera is powered down and back on. OFF regenerates the Timecode upon repowering.)
00040004 FIRST REC TC REGEN (Selects how Timecode is Regenerated when recording is started. Two options: REGEN (default) and PRESET.)
00040005 P.OFF LCD DISPLAY ON (When the camera is powered down, this allows the LCD window display to remain ON or OFF.)
00040006 TC OUT TCG (Selects how Timecode is output from the camera. TCG/TCR allows the Timecode Generator (TCG) output in EE mode, and the Timecode reader value output in V-V mode.)
00040007 VITC UB MODE TIME (Selects what is to be written to VITC User Bits. Five Options: USER, DATE, TIME, EXT, or TCG.)
00040008 TC DISP SEL 30 (Options are 24, 25, and 30. Selects how the frames count up i.e. 0 to 23fps, 0 to 24fps, or 0 to 29fps.)

MONITOR MARKER MENU

00120003 SAFETY ZONE OFF (Selects a 90% Safety Area frameline for 16x9 or 4x3.)
00120004 CENTER MARKER ON (Turns Center Cross on or off.)
00120005 FRAME SIG 4:3 (Sets embedded Framelines. The options are 4:3, 14:9, VISTA 1:1.85, and CNSCO 1:1.235)
00120006 FRAME MARK ON (Turns the above Framelines and Markers on or off.)

VTR VF INDICATOR MENU (Set how the following information is displayed in the viewfinder:)

00050001 TAPE(IND) ON (Turns remaining tape indicator in the viewfinder ON or OFF.)
00050002 BATTERY(IND) ON (Turns the battery voltage display in the viewfinder ON or OFF.)
00050003 LEVEL METER(IND) CH1 (Selects what is displayed on the audio level meter in the viewfinder i.e CH1 or CH1+2, or turns it OFF.)
00050004 AUDIO IN(IND) OFF (Turns the audio input display in the viewfinder ON or OFF.)
00050005 TC(IND) OFF (Choice of 3 modes for displaying timecode in the viewfinder, or OFF.)
00050006 VTR WARNING(IND) NORMAL (Sets how VTR warnings are displayed in the viewfinder. NORMAL is a momentary 3-second display, and ALWAYS is always on once triggered.)
00050007 COMPRESSION(IND) ON (When ON, "COMP" is shown in the top right of the viewfinder indicating that Dark Compression is being used.)
00050008 SAVE LED SAVE (A Save indicator lights in the viewfinder. SAVE&TAPE causes the indicator to flash as tape nears the end.)

BATTERY/TAPE MENU

00060001 AJ-BP490(TYPE) ON (For the AJ-BP490 and the PACO HP-90A battery.)
00060002 AU-BP402(TYPE) ON (For the AU-BP402 battery.)
00060003 HP30A(TYPE) ON (For the PACO HP30A battery.)
00060004 PRO14(TYPE) ON (For the Anton/Bauer PRO14 battery.)
00060005 TRIM14(TYPE) ON (For the Anton/Bauer TRIM14 battery.)
00060006 TRIM13(TYPE) ON (For the Anton/Bauer TRIM13 battery.)
00060007 DIGITAL14(TYPE) ON (For the Anton/Bauer 14V DIGITAL14 battery.)
00060008 DIGITAL13(TYPE) ON (For the Anton/Bauer 13V DIGITAL13 battery.)
00060009 BP-H90(TYPE) ON (For the IDX BP-H90 battery.)
00060010 BP-H100(TYPE) ON (For the IDX BP-H100 battery.)
00060011 NP-L40(TYPE) ON (For the IDX NP-L40 battery.)
00060012 NP-L40 D(TYPE) ON (For the IDX NP-L40D battery.)
00060013 BP-L60/90(TYPE) ON (For the Sony BP-L60/90 battery.)
00060014 NP-1B(TYPE) ON (For the Sony NP-1B battery.)
00060015 DIONIC90(TYPE) ON (For the Anton/Bauer DIONIC90 Digital battery.)
00060016 DIONIC160(TYPE) ON (For the Anton/Bauer DIONIC160 Digital battery.)
00060017 NP-L50(TYPE) ON (For the IDX NP-L50 battery.)
00060018 ENDURA50(TYPE) ON (For the IDX ENDURA50 battery.)
00060019 ENDURA-D(TYPE) ON (Use when mounting the IDX, V-mount adapter plate, in order to use digital batteries.)

00060001 AJ-BP490(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060002 AU-BP402(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060003 HP30A(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060004 PRO14(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060005 TRIM14(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060006 TRIM13(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060007 DIGITAL14(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060008 DIGITAL13(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060009 BP-H90(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060010 BP-H100(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060011 NP-L40(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060012 NP-L40 D(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060013 BP-L60/90(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060014 NP-1B(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060015 DIONIC90(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060016 DIONIC160(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060017 NP-L50(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060018 ENDURA50(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)
00060019 ENDURA-D(MODE) AUTO (This means the voltage at which the low-battery warning is triggered is set to the factory default value. This can be changed by the user if set to MANUAL.)

00060001 AJ-BP490(MANUAL VOLT) 11.7V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060002 AU-BP402(MANUAL VOLT) 11.2V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060003 HP30A(MANUAL VOLT) 11.5V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060004 PRO14(MANUAL VOLT) 13.7V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060005 TRIM14(MANUAL VOLT) 13.7V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060006 TRIM13(MANUAL VOLT) 12.6V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060007 DIGITAL14(MANUAL VOLT) 13.3V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060008 DIGITAL13(MANUAL VOLT) 12.6V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060009 BP-H90(MANUAL VOLT) 11.2V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060010 BP-H100(MANUAL VOLT) 11.2V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060011 NP-L40(MANUAL VOLT) 11.9V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060012 NP-L40 D(MANUAL VOLT) 11.9V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060013 BP-L60/90(MANUAL VOLT) 11.4V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060014 NP-1B(MANUAL VOLT) 11.3V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060015 DIONIC90(MANUAL VOLT) 13.6V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060016 DIONIC160(MANUAL VOLT) 12.7V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060017 NP-L50(MANUAL VOLT) 12.2V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060018 ENDURA50(MANUAL VOLT) 12.8V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)
00060019 ENDURA-D(MANUAL VOLT) 12.9V (The voltage at which the low-battery warning is triggered can be adjusted here by the user. Only effective if mode is set to MANUAL above.)

USER MENU SELECT

00070001 *NEWS REC MODE OFF (Turn ON to have this item appear in the User Menus.)
00070002 *HUMID OPE OFF (Turn ON to have this item appear in the User Menus.)
00070003 *REC START OFF (Turn ON to have this item appear in the User Menus.)
00070004 *PAUSE TIMER OFF (Turn ON to have this item appear in the User Menus.)
00070005 *RETAKE MODE OFF (Turn ON to have this item appear in the User Menus.)
00070006 *HD SDI OUT OFF (Turn ON to have this item appear in the User Menus.)
00070007 *INTERVAL REC MODE OFF (Turn ON to have this item appear in the User Menus.)
00070008 *INTERVAL REC TIME OFF (Turn ON to have this item appear in the User Menus.)
00070009 *INTERVAL PAUSE TIME OFF (Turn ON to have this item appear in the User Menus.)
00070010 *ECU REC CHK SW OFF (Turn ON to have this item appear in the User Menus.)
00070011 *CHARACTER ON SDI OFF (Turn ON to have this item appear in the User Menus.)
00070012 *COMPRESSION MODE OFF (Turn ON to have this item appear in the User Menus.)
00080001 *BATTERY SELECT OFF (Turn ON to have this item appear in the User Menus.)
00080002 *EXT DC IN SELECT OFF (Turn ON to have this item appear in the User Menus.)
00080003 *BATT NEAR END ALARM OFF (Turn ON to have this item appear in the User Menus.)
00080004 *BATT NEAR END CANCEL OFF (Turn ON to have this item appear in the User Menus.)
00080005 *BATT END ALARM OFF (Turn ON to have this item appear in the User Menus.)
00080006 *BATT REMAIN FULL OFF (Turn ON to have this item appear in the User Menus.)
00080007 *TAPE NEAR END ALARM OFF (Turn ON to have this item appear in the User Menus.)
00080008 *TAPE NEAR END TIME OFF (Turn ON to have this item appear in the User Menus.)
00080009 *TAPE END ALARM OFF (Turn ON to have this item appear in the User Menus.)
00080010 *TAPE REMAIN/ OFF (Turn ON to have this item appear in the User Menus.)
00130004 *SAFETY ZONE OFF (Turn ON to have this item appear in the User Menus.)
00130005 *CENTER MARKER OFF (Turn ON to have this item appear in the User Menus.)
00130006 *FRAME SIG OFF (Turn ON to have this item appear in the User Menus.)
00130007 *FRAME MARK OFF (Turn ON to have this item appear in the User Menus.)
00090001 *TAPE(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090002 *BATTERY(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090003 *LEVEL METER(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090004 *AUDIO IN(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090005 *TC(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090006 *VTR WARNING(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090007 *COMPRESSION(IND) OFF (Turn ON to have this item appear in the User Menus.)
00090008 *SAVE LED OFF (Turn ON to have this item appear in the User Menus.)
00100001 *FRONT MIC POWER OFF (Turn ON to have this item appear in the User Menus.)
00100002 *MIC LOWCUT CH1 OFF (Turn ON to have this item appear in the User Menus.)
00100003 *MIC LOWCUT CH2 OFF (Turn ON to have this item appear in the User Menus.)
00100004 *LIMITER OFF (Turn ON to have this item appear in the User Menus.)
00100005 *TEST TONE OFF (Turn ON to have this item appear in the User Menus.)
00100006 *REC CH3/CH4 OFF (Turn ON to have this item appear in the User Menus.)
00100007 *CUE SELECT OFF (Turn ON to have this item appear in the User Menus.)
00100008 *CUE REC OFF (Turn ON to have this item appear in the User Menus.)
00100009 *EMBEDDED AUDIO(60Hz) OFF (Turn ON to have this item appear in the User Menus.)
00100010 *A/V SYNCHRO OFF (Turn ON to have this item appear in the User Menus.)
00110001 *TC MODE OFF (Turn ON to have this item appear in the User Menus.)
00110002 *UB MODE OFF (Turn ON to have this item appear in the User Menus.)
00110003 *TCG SET HOLD OFF (Turn ON to have this item appear in the User Menus.)
00110004 *FIRST REC TC OFF (Turn ON to have this item appear in the User Menus.)
00110005 *P.OFF LCD DISPLAY OFF (Turn ON to have this item appear in the User Menus.)
00110006 *TC OUT OFF (Turn ON to have this item appear in the User Menus.)
00110007 *VITC UB MODE OFF (Turn ON to have this item appear in the User Menus.)
00110008 *TC DISP SEL OFF (Turn ON to have this item appear in the User Menus.)



The Battery-Type Menu Options with their corresponding Low-Battery Warning Trigger Points:

Sony BP-L60/90 battery - triggers at 11.4V
Sony NP-1B battery - triggers at 11.3V
Anton/Bauer PRO14 battery - triggers at 13.7V
Anton/Bauer TRIM14 battery - triggers at 13.7V
Anton/Bauer TRIM13 battery - triggers at 12.6V
Anton/Bauer 14V DIGITAL14 battery - triggers at 13.3V
Anton/Bauer 13V DIGITAL13 battery - triggers at 12.6V
Anton/Bauer DIONIC90 Digital battery - triggers at 13.6V
Anton/Bauer DIONIC160 Digital battery - triggers at 12.7V
IDX BP-H90 battery - triggers at 11.2V
IDX BP-H100 battery - triggers at 11.2V
IDX NP-L40 battery - triggers at 11.9V
IDX NP-L40D battery - triggers at 11.9V
IDX NP-L50 battery - triggers at 12.2V
IDX ENDURA50 battery - triggers at 12.8V
IDX Digital - use when mounting the IDX, V-mount adapter plate, in order to use digital batteries - triggers at 12.9V
Panasonic AJ-BP490 - triggers at 11.7V
PACO HP-90A battery - triggers at 11.7V
The AU-BP402 battery - triggers at 11.2V
PACO HP30A battery - triggers at 11.5V



Disclaimer: While I check the information presented here as thoroughly as possible (...through actual work experience, personal testing, and consulting other experts in the field), I can not absolutely guarantee its complete accuracy. These writings really reflect my own evolving understanding of these particular issues as I try and piece everything together myself. These pages are works in progress, and will be corrected and updated as new information comes to hand. Any and all feedback is very gratefully accepted. Especially any information that helps to correct outright mistakes in this presentation, or additional information that helps to expand the scope of these discussions.



Copyright © Peter Gray (March 8th, 2006)



line.gif - 3.0 K

Peter Gray
(in California)
P.O. Box 5132
Pine Mountain Club, CA 93222
United States of America
telephone: +1(661) 242-1234

dp@petergray.org

e-mail annimation.gif - 4.20 K

  top.jpg - 1.98 K  
back.jpg - 2.28 K   next.jpg - 2.20 K
  home.jpg - 2.13 K